| These smaller-sized, lightweight cylinders require no deposite or monthly rental charge. They are easier to handle and use very little space. They also eliminate over-purchasing when only small quantities are necessary. For greater confidence, all stock calibration gas mixtures are analyzed against NIST traceable standards where available. Ask your NorLab representative for a part number cross-reference sheet to help you match your instrument manufacturer's part number. | ![]() |
Nonreactive Gases
![]() |
The 103 liter cylinder is recommended for nonreactive gas mixtures and pure gases such as Argon, Nitrogen, Nitrous Oxide, and Helium. This cylinder combines a convenient size with enough capacity to handle even your most rigorous calibration requirements. |
Gas mixtures are certified to an analytical accuracy as follows:
10 ppm to 49 ppm ±5% of the minor components
50 ppm to 50% ±2% of the minor components
| Cylinder Size |
Cu. ft. | Service Pressure PSIG |
Dimensions Length |
Inches OD |
Material | Recommended Requlator |
DOT Specification |
Outlet Fitting |
| 103 liter | 3.6 | 1000 | 13-27/32" | 3-1/4" | steel | 511,512,514,515 516,517,518 |
39 NRC | 5/8"-18 UNF |
NOTE: Top pressure and volume will be reduced if concentration is greater than: Heptane
750 ppm(7.1% LEL)-Toluene 700 ppm(5.5%LEL)-Hexane .2%(17% LEL)-Pentane .56%(40% LEL)
¡@
| New offerings of laser, blood gas, and lung diffusion medical mixtures give NorLab an added dimension few other suppliers offer. This medical "E" style, 550 liter, 2200 PSIG, non-returnable cylinder, valved with the appropriate CGA fitting completes the package. This cylinder is recommended where larger amounts of non-reactive pure gases or mixtures are required without sacrificing portablity. Contact NorLab for other mixtures not listed. |
![]() |
| ¡@ *Medical mixtures produced under Norco, Inc.'s FDA license. |
| The 58 liter cylinder is manufactured of aluminum and is
recommended for mixtures that are not stable in steel cylinders. These include Hydrogen
Sulfide, Sulfur Dioxide, Nitrogen Dioxide, Nitric Oxide and Ammonia. Gas mixtures in Nitrogen are certified to an analytical accuracy as follows: 5-24ppm ±10% of the minor components |
![]() |
¡@
| Cylinder Size |
Cu. ft. | Service Pressure PSIG |
Dimensions Length |
Inches OD |
Material | Recommended Requlator |
DOT Specification |
Outlet Fitting |
| 58 liter | 2.0 | 500 | 14-1/2" | 3-1/2" | aluminum | 511,512,514,515 516,517,518 |
39 NRC | 5/8"-18 UNF |
NOTE:Gas mixtures for reactive gases with air are certified to an analytical accuracy of
±10% of the minor components.
¡@
| The 17 liter cylinder is recommended for gas mixtures where only a small quantity is required. This includes LEL (Lower Explosive Limit), Carbon Monoxide, and other nonreactive mixtures. | |
| Gas mixtures are certified to an analytical accuracy as
follows: 10 ppm to 49 ppm ±5% of the minor component |
![]() |
| Cylinder Size |
Cu. ft. | Service Pressure PSIG |
Dimensions Length |
Inches OD |
Material | Recommended Requlator |
DOT Specification |
Outlet Fitting |
| 17 liter | 0.6 | 240 | 11" | 2-7/8" | steel | 400,411,413 415,416,417,418 |
39 NRC | CGA 600 |
¡@
![]() |
Calibration Kits, Cases and AcessoriesNorLab offers custom calibration kits upon request. Our two-, three-, or four-bottle cases make a safe and convenient method for transporting and storing your NorLab calibation standards. Fill these cases with any combination of gas concentrations or cylinder sizes offered and make instrument calibration a snap. Add a regulator or flow meter and your custom calibration kit is complete! |
¡@
Regulator and Flow MetersNorLab offers a complete line fo regulators or flow meters to meet flow rate specifications for calibrating atmospheric and laboratory instrumentation. |
![]() |
¡@
| FLOW | TO OBTAIN | |||||||
| cm3/min | cm3/sec | ft3/hr | ft3/min | m3/hr | m3/min | L/hr | Lpm | |
| MULTIPLY | ___ | 0.0166667 | BY | |||||
| cm3/min | 60 | ___ | 0.0021189 | 0.0000353 | 0.00006 | 0.000001 | 0.06 | 0.001 |
| cm3/sec | 471.9474 | 7.865790 | 0.1271340 | 0.0021189 | 0.0036 | 0.00006 | 3.6 | 0.06 |
| ft3/hr | 28316.85 | 471.9474 | ___ | 0.0166667 | 0.283168 | 0.0004719 | 28.31685 | 0.4719474 |
| ft3/min | 16,666.67 | 277.7778 | 60 | ___ | 1.699008 | 0.283168 | 1699.008 | 28.31685 |
| m3/hr | 1000,000 | 16,666.67 | 35.31467 | 0.5884777 | ___ | 0.0166667 | 1000 | 16.66667 |
| m3/min | 16.66667 | 0.2777778 | 2118.876 | 35.31467 | 80 | ___ | 60,000 | 1000 |
| L/hr | 1000 | 16.66667 | 0.0353147 | 0.0005885 | 0.001 | 0.0000167 | ___ | 0.0166667 |
| Lpm | 2.118876 | 0.0353147 | 0.06 | 0.001 | 60 | ___ | ||
| VOLUME | TO OBTAIN | |||||||
| cm3* | ft3 | in3 | m3 | gal(U.S.liquid) | L | |||
| MULTILY | BY | |||||||
| cm3 | ___ | 0.000003531 | 0.0610237 | 0.000001 | 0.000641 | 0.001 | ||
| ft3 | 28,316.847 | ___ | 1728 | 0.2831685 | 7.480519 | 28.316847 | ||
| in3 | 16.387064 | 0.0005787 | ___ | 0.00001637 | 0.0043290 | 0.0163871 | ||
| m3 | 1,000,000 | 35.31467 | 61,023.74 | ___ | 264,172 | 1000 | ||
| gal(u.s.liquid) | 3785,412 | 0.13368056 | 231 | 0.00378541 | ___ | 3.785412 | ||
| L | 1000 | 0.03531467 | 61,02374 | 0.001 | 0.2641721 | ___ | ||
¡@